Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Braz. dent. j ; 24(4): 322-325, July-Aug/2013. tab, graf
Article in English | LILACS | ID: lil-689817

ABSTRACT

The aim of this study was to evaluate the vertical marginal gap of sintered gold copings and metal-ceramic crowns with different finish line preparations: a beveled round shoulder (BRS) and a beveled long chamfer (BLC), testing the null hypotheses that there are no differences in marginal gap regardless of finish line and phase of restoration (coping or crown). Stainless steel master models were fabricated to simulate tooth preparation for metal-ceramic crowns with different finish lines (BRS and BLC). Ten dies were obtained from each model. Preparations were coated with 2 layers of spacer to 1 mm from the margin. Sintercast gold copings were prepared, sintered and adjusted to the dies. The copings (n=10) were placed onto the master model and the marginal gap was measured in 24 equidistant points using optical microscopy (X230). An opaque and two body ceramic layers were subsequently applied to the copings and the same measuring procedure was performed for the crowns. The data were analyzed statistically using paired and unpaired Student's t-test (α=0.05). Mean marginal gap values (µm) for the copings and crowns were, respectively: 113.6 and 117.1 for the BRS; and 58.2 and 74.3 for the BLC preparation. Significantly greater marginal gaps (p=0.0307) were found for restorations with BRS than with BLC finish line, which also showed statistically significant differences in the gap size between coping and crown (p=0.001). In conclusion, marginal gap is influenced by ceramic application on copings fabricated on BLC preparation, and greater marginal gaps were found for restorations with BRS finish line, rejecting the experimental null hypotheses.


O objetivo deste estudo foi avaliar a fenda marginal vertical de copings de ouro sinterizado e coroas metalo-cerâmicas com diferentes tipos de término de preparo: ombro arredondado biselado (OAB) e chanfro longo biselado (CLB), testando a hipótese nula de que não há diferenças na adaptação marginal quando se compara o tipo de término ou a fase da restauração (coping ou coroa). Modelos de aço inoxidável foram confeccionados simulando preparos dentais com diferentes términos (OAB e CLB). Dez modelos de gesso foram confeccionados a partir de cada preparo. Duas camadas de espaçador foram passadas em cada preparo, a 1 mm da margem. Os copings de Sintercast confeccionados, sinterizados e ajustados ao modelo de gesso. Os copings (n=10) foram colocados no modelo de aço e a fenda marginal foi medida em 24 pontos equidistantes por meio de microscópio óptico (×230). Uma camada de opaco e duas de porcelana feldspática foram aplicadas sobre os copings e o mesmo processo de mensuração de fenda foi utilizado para as coroas. Os dados foram analisados estatisticamente usando o teste t Student pareado e não-pareado (α=0,05). Os valores médios de fenda marginal (µm) para os copings e coroas foram, respectivamente: 113,6 e 117,1 para OAB; e 58,2 e 74,3 para CLB. Fendas marginais significantemente maiores (p=0,0307) foram observadas nas restaurações com términos OAB quando comparados ao término CLB, o qual mostrou diferenças estatísticas na comparação entre coping e coroa (p=0,001). Em conclusão, a fenda marginal é influenciada pela aplicação de cerâmica em copings fabricados com términos CLB, e fendas marginais maiores foram observadas para restaurações com término OAB, rejeitando-se as hipóteses nulas.


Subject(s)
Crowns , Dental Materials , Gold , Dental Prosthesis Design
2.
Ciênc. odontol. bras ; 10(2): 10-15, abr.-jun. 2007.
Article in English | LILACS, BBO | ID: lil-518109

ABSTRACT

Objective: To evaluate different methods of additional polymerization in the VickersÆ microhardness of three composite resins. Material and Methods: With assistance of a metallic matrix (3 x 4mm), 30 specimens (sps) of each direct resincomposite (drc) were prepared, entitled: Filtek Z250(3M ESPE, Saint Paul/MN-USA)(Gr1), W3D(Wilcos, Petrópolis/RJ-Brazil)(Gr2), and EstheticX (Dentsply/York/PA-USA)(Gr3). All sps were photopolimerized, by the incrementaltechnique, during 40 seconds (Gr1 - n=10: control). After that, 20 samples of each group were divided and half of thesamples (n=10) were submitted to the additional polymerization during 15 minutes to 127ºC in autoclave (Gr2) and theother half in stove (Gr3). After all sps were stored in distilled water (37ºC/24 hours). The microhardness was accomplishedin digital machine (Future-Tech, FM 700 Model), with 50kg of load. The data obtained (Kg/mm2) were analyzedutilizing the ANOVA Test (2 factors) and Tukey test (p<0.05). Results: The values of mean ± standard deviations obtainedwere: Gr1a(84,2±5,1), Gr1b (71,6±6,7), Gr1c (89,6±7,4), Gr2a (101,1±6,0), Gr2b (96,4±9,0), Gr2c (112,6±7,3), Gr3a(74,0±6,5), Gr3b (66,0±12,7) e Gr3c (81,7±6,5). The polymerization in stove produced a higher microhardness than theother kinds of polymerization (p<0.05) and the microhardness of the resins statistically differed among them (p<0.05).Conclusion: The additional polymerization of the Filtek Z250 in the stove produced microhardness statistically higherthan the others.


Objetivo: Frente à possibilidade de se utilizar resinas compostas diretas (rcds) para procedimentos restauradores indiretos,o presente estudo propôs avaliar diferentes métodos de polimerização adicional na microdureza VickersÆ de trêsresinas compostas de uso direto. Materiais e Métodos: Com o auxílio de uma matriz metálica (3,0 x 4,0mm), foramconfeccionados 30 corpos-de-prova de cada resina denominadas: W3D(Wilcos/Brasil)(Gr1), Z250(3M ESPE/EUA)(Gr2) e Esthetic X(Dentisply/EUA)(Gr3). Todos os espécimes (sps) foram fotopolimerizados, pela técnica incremental,durante 40 segundos (Gr1 - n=10: controle). Em seguida, 20 amostras de cada grupo foram aleatoriamente divididas emetade das amostras (n=10) submetidas à polimerização adicional durante 15 minutos a 127ºC em autoclave (Gr2) e aoutra parte em estufa (Gr3). Após todos os sps foram armazenados em água destilada a 37ºC durante 24 horas. O testede microdureza foi realizado em microdurômetro (Future-Tech, Modelo FM 700), com força de 50 kg. Os dados obtidos(Kg/mm2) foram analisados utilizando o teste ANOVA (2 fatores) e o teste t (Tukey) (p<0.05). Resultados: Os valores demédias±desvios padrões obtidos foram: Gr1a(84,2±5,1), Gr1b (71,6±6,7), Gr1c (89,6±7,4), Gr2a (101,1±6,0), Gr2b(96,4±9,0), Gr2c (112,6±7,3), Gr3a (74,0±6,5), Gr3b (66,0±12,7) e Gr3c (81,7±6,5). Observou-se que a polimerizaçãoem estufa gerou maior microdureza que as demais polimerizações (p<0,05) e que a microdureza das resinas diferiuestatisticamente entre si (p<0,05). Conclusão: Dessa forma, é lícito concluir que a polimerização adicional da Z250na estufa gerou microdureza estatisticamente superior aos demais grupos.


Subject(s)
Composite Resins , Hardness Tests , Analysis of Variance
3.
São José dos Campos; s.n; 2001. 117 p. ilus, tab. (BR).
Thesis in Portuguese | LILACS, BBO | ID: lil-399573

ABSTRACT

A biocompatibilidade de quatro agentes para cimentação de peças protéticas foi avaliada por meio de implantes em tecido conjuntivo subcutâneo de ratos. Neste trabalho foram avaliados um cimento de fosfato de zinco (Lee Smith - Vigodent), um cimento de ionômero de vidro (Ketac-Cem - ESPE) e dois cimentos resinosos (Panavia Ex 21 - Kuraray Co.; Enforce - Dentsply). Após a manipulação dos cimentos, os implantes foram realizados, utilizando-se tubos de polietileno preenchidos com os agentes cimentantes e inseridos em lojas cirúrgicas preparadas no dorso dos animais, os quais foram sacrificados nos períodos de observação de 14, 30, 60 e 84 dias. Os tecidos circunjacentes aos implantes foram removidos, incluídos em parafina e corados com hematoxilinae e eosina para análise em microscopia óptica. Os resultados mostraram que todos os agentes de cimentação causaram uma resposta tecidual nos períodos avaliados; o cimento de fosfato de zinco apresentou um menor grau de reação tecidual nos períodos de 14, 30 e 60 dias; o cimento de ionômero de vidro apresentou as piores características de biocompatibilidade quando em contato com o tecido conjuntivo de ratos


Subject(s)
Biocompatible Materials , Dental Cements
SELECTION OF CITATIONS
SEARCH DETAIL